We present a modern and efficient pellet boiler, model PELLPAL DUO with a power of 75 kW. This device is adapted to fuel in the form of wood pellets. The PELLPAL DUO boiler is characterized by very high efficiency, thoughtful construction, and excellent insulation of the device.
The PELLPAL DUO boiler with a power of 75 kW will easily handle generating the energy necessary to heat rooms while simultaneously heating domestic hot water. The fuel used in PELLPAL DUO boilers is wood pellet with a diameter of 6 to 8 mm. The fuel itself is very easy to store, does not produce dust, and at the same time leaves a minimal amount of ash after combustion.
The thermal efficiency of the PELLPAL DUO pellet boiler with a power of 75 kW exceeds 90%, as confirmed by tests conducted according to the PN-EN 303-5:2021-09 standard, in which the heating device received class 5. The energy class of the central heating boiler is A+, which certifies the energy efficiency and exceptional performance of the equipment. Combined with the low emission level of carbon monoxide, tar substances, and dust (at a level below 20 mg/m3), this allows for higher subsidies for boiler replacement according to the EcoDesign eco-project.
Very high efficiency and performance of the device.
The equipment of the PELLPAL DUO pellet boiler with a power of 75 kW includes:
- a steel-cast iron burner that efficiently burns pellets,
- a forced draft fan that supplies air to the combustion chamber,
- the PELLPAL DUO controller, which is responsible for ignition, maintaining, and controlling the combustion process by regularly supplying fuel.
The boiler is designed to operate in an open system (system equipped with an overflow expansion vessel), in which the installation is directly connected to the air accumulated in the vessel. However, if there is a need to use it in a closed system, the purchase of additional components such as a cooling coil, DBV2 safety valve, SYR 5067 thermal protection, and a diaphragm expansion vessel will be necessary. These devices will eliminate the risk of overpressure, which can be dangerous for the installed system.
Construction of the PELLPAL DUO pellet boiler with a power of 75 kW
The Pellpal Duo heating boiler with a power of 75 kW consists of a body made of certified boiler plate with a thickness of 5 mm and a water jacket made from the same certified steel of the same thickness. The boiler is designed with horizontal channels in the upper part of the device. The boiler body is designed so that the pellet burner can be mounted on the right or left side of the device. The boiler is equipped with a dedicated shutter that allows changing the position of the feeder side relative to the boiler body. It is usually delivered with the feeder and tank mounted on the right side of the boiler.
Directly above the feeder, a preliminary fuel tank for pellets is installed. An external fuel feeder should be used for the boiler, e.g., from a large pellet tank or BigBag.
Fuel from the tank is poured directly into the screw feeder and transported in appropriate amounts to the burner combustion chamber inside. The PELLPAL DUO boiler has a safety device called a "fire guard", which prevents the backflow of embers and fire into the fuel chamber. At the rear of the boiler, there is a water tank connected by a hose to a temperature sensor. If the sensor detects too high a temperature in the feeder, water is discharged, and the burner is shut down as an emergency measure.
Control of the PELLPAL DUO boiler with a power of 75 kW
The operation of the heating boiler is controlled by a microprocessor controller of the PELLPAL DUO boiler. It has preset settings for fuel in the form of pellets. The controller menu includes an option to change the fuel depending on the heating boiler in which the device is used. For PELLPAL DUO boilers tested for pellet combustion, it has preset settings for pellet fuel and settings adapted to the specific heating power of the boiler. The parameters are selected so that the ignition process and subsequent burning and water heating in the central heating system proceed efficiently and economically. The controller has an automatic pellet ignition function in the burner using an igniter (automatic heater) located in the combustion chamber.
Equipment of the PELLPAL DUO boiler with a power of 75 kW:
- boiler body with insulation
- preliminary pellet tank
- PELLPAL DUO microprocessor controller
- pellet feeder and burner with automatic igniter
- combustion chamber forced draft fan, DM 80 blower
Documentation included with the boiler equipment:
- operation and installation manual for the PELLPAL DUO pellet boiler
- operation manual for the PELLPAL DUO controller
- boiler test certificate - integral part of the boiler operation manual
- boiler test report - as above
- boiler conformity declaration - as above
- boiler product card - as above
- eco-design requirements card - as above
- boiler nameplate - placed on the heating device
- boiler energy label - for central heating boilers with power above 70 kW, an energy label is not required
The warranty for the PELLPAL DUO boiler is 60 months and starts from the date of its issuance and the purchase of the boiler. The warranty on the boiler is granted provided that all the requirements given in the operating manual are met (see attachments).
Attention! Failure to familiarize with and meet the requirements given in the operating manual by the user, attempts at self-repair, interference with the boiler's construction and equipment, and other causes not resulting from the manufacturer's fault will result in the loss of the warranty.
The warranty also covers the equipment installed on the boiler (fan, controller), but for the period and under the conditions consistent with the warranty card of the manufacturer of this equipment.
The warranty does not cover:
- mechanical damage occurring during transport, installation, boiler operation
- components that wear out during boiler operation (sealing cord, gaskets, swirlers, hinges, screws, nuts, auger safety pin, handles and hooks, ceramic elements, flame deflector, paint coatings). The warranty also does not cover the replacement of these parts
- pellet ignition heaters as a product naturally wearing out during normal operation are subject to a 1-month warranty from the moment of the first boiler ignition or replacement
- events described in "Causes of disturbances and malfunctions in boiler operation"
- lack of confirmation of boiler installation and protection according to PN-91/B-02413 or PN-EN 12828:2003
- activities intended to be performed by the user as specified in the operating manual
- corrosion, pitting, and material loss of the boiler caused by improper boiler operation (maintaining the minimum return temperature in the boiler - temperature protection)
- damage and their effects caused by failure to use chimney ducts that do not meet the requirements considering the likelihood of flue gas condensation and resistance to harmful chemical compounds including acids.
- damage resulting from exceeding the maximum temperature and pressure values in the boiler